Ø d1
6 mm
S
1,5 mm
Belastungsfall I
663 bar
Please choose a variant
Article
PR 06-1 ZP
PR 06-1.5 ZP
PR 08-1 ZP
PR 08-1.5 ZP
PR 10-1 ZP
PR 10-1.5 ZP
PR 12-1 ZP
PR 12-1.5 ZP
PR 12-2 ZP
PR 15-1.5 ZP
PR 15-2 ZP
PR 16-2 ZP
PR 16-2.5 ZP
PR 18-1.5 ZP
PR 18-2 ZP
PR 20-2 ZP
PR 20-2.5 ZP
PR 20-3 ZP
PR 22-1.5 ZP
PR 22-2 ZP
PR 22-2.5 ZP
PR 25-2.5 ZP
PR 25-3 ZP
PR 25-4 ZP
PR 28-1.5 ZP
PR 28-2 ZP
PR 28-2.5 ZP
PR 28-3 ZP
PR 30-3 ZP
PR 30-4 ZP
PR 30-5 ZP
PR 35-2 ZP
PR 35-2.5 ZP
PR 35-3 ZP
PR 38-4 ZP
PR 42-2 ZP
PR 42-3 ZP
Register now to get access to our online shop
Register now and access our complete product range and many exclusive services.
Product details for
PR 06-1.5 ZP
Ø d1
6 mm
S
1,5 mm
Belastungsfall I
663 bar
Belastungsfall III
524 bar
Ø d2
3 mm
AD-Toleranz +/-
0,08 mm
ID-Toleranz +/-
0,15 mm
All characteristics
Characteristics
Ausführung
- metrisch
Bauart
- Präzisionsstahlrohr, nahtlos (kalt gezogen), metrisch
Materialzustand
- (+N) = normalisierend geglüht
Norm
- DIN EN 10305-4
Oberfläche
- organische Deckschicht EPOXY ≤ 50 μm
Werkstoff
- Stahl E235+N (1.0308)
Farbe
- schwarz RAL 9005
Rohrlänge
- 6 Meter
Zolltarifnummer
- 73043120
All characteristics
Product description
Notes
The appropriate wall thickness needs to be calculated for tubes with bends as stipulated in DIN EN 13480-4.
Description
--
The steel pipes in the PR ZP, PR VZ CF PR and PR ST 52 series are supplied in the +N condition (normalised annealed) as standard. This delivery condition ensures excellent bendability and is the established standard for use in hydraulic piping systems, particularly during assembly and installation.
Further information
Specific load I: static (up to 120 °C)
Load case III: dynamic (up to 120 °C) stress range = P bar
Working stroke= P bar
Strength parameter: K 235 [N/mm²]
Safety coefficient: S 1.5
Fatigue strength: σSch/D 225 [N/mm²]
Tolerances: DIN EN 10305-1 (diameter-/wall thickness indication)
Ordering information
Product variants
37 Results
Search
Show dimensional drawing
Identifier
Shows 10 of 37
Column selection
Ø d1 (mm)
S (mm)
Specific load I (bar)
Specific load III (bar)
Ø d2 (mm)
AD tolerance +/- (mm)
ID tolerance +/- (mm)